RF Budget Analyzer calculating noise figure incorrectly

4 vues (au cours des 30 derniers jours)
Jarrett Pischera
Jarrett Pischera le 15 Août 2024
Réponse apportée : Pratyush le 21 Août 2024
I am currently using the RF Toolbox, to generate cascades using s-parameter files with the RF Budget Analyzer.
When I insert a passive component into the tool, It returns a noise figure value that is not equal to the negative of the Gain (Insertion loss in this case). Does anyone know what could cause this? This occurs even if I import a single S-parameter file, as the only part in the cascade.

Réponses (1)

Pratyush
Pratyush le 21 Août 2024
Hi Jarret,
In MATLAB's RF Toolbox, when using the RF Budget Analyzer, a passive component's noise figure should equal the negative of its gain (insertion loss). Discrepancies can arise due to:
1. Incorrect S-parameter file format or units.
2. Mismatched reference impedance.
3. Frequency range differences.
4. Impedance mismatches causing mismatch losses.
5. Misconfigured tool settings.
6. Data interpolation issues.
7. Numerical precision errors.
To troubleshoot, verify the S-parameter file, ensure correct settings, test with known parameters.

Catégories

En savoir plus sur Data Import and Network Parameters dans Help Center et File Exchange

Produits

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!