Simulink data type conversion, single to uint16.
Afficher commentaires plus anciens
Hello,
I'm using simulink and I need to convert from a single to a uint16.
Could a kind soul kindly explain why the output of a single (with range 0-2pi) equates to an uint16 of zero?
Here is an example:

And here is the output of that example:

There are a number of uint16 signals in my model with range 0-4000 (I am reading from sevreral ADC). All behave as expected. Just this conversion, in this instance.
5 commentaires
Daniel
le 18 Sep 2024
What is happening to that value downstream? Are you generating code? Is it being used for trigonometry?
Walter Roberson
le 18 Sep 2024
Are you using the Data Type Conversion Block? https://www.mathworks.com/help/simulink/slref/datatypeconversion.html
Walter Roberson
le 18 Sep 2024
I would expect single range 0 to 2*pi to convert to uint16 values 0, 1, 2, 3, 4, 5 or 6.
Data type conversion does not do any scaling to match the range. For example it is not going to scale 0 to 2*pi to 0 to 62831
Jamie
le 25 Sep 2024
Réponse acceptée
Plus de réponses (0)