Hello,
When running a simulation on an Arduino Mega 2560 through monitor and tune, I cannot change the position of any manual switch in my block diagram. I am running the simulation on the board and the sim is running on external mode through XCP on Serial. Any help would be much appreciated.
2 commentaires
Abhinav Aravindan
le 8 Oct 2024
Could you share the Simulink model file to understand the issue better?
Réponse acceptée
Amal Raj
le 28 Oct 2024 à 10:08
Hi Malek, I think you are faced with a bug in 2024b.
The workaround would be to update Default Parameter Behavior parameter drop-down value to Tunable in the config set.
This will solve the issue you are facing. You can even try working with other versions of MATLAB, and you should be fine.
Regards,
Amal
1 commentaire
Vorrapath Kokaew
le 29 Oct 2024 à 12:04
Modifié(e) : Vorrapath Kokaew
le 29 Oct 2024 à 12:09
So, do I. I use ESP32 with arduino package that message shown Cannot change the model '.......' while the simulation is running. Anyway, I already follow the Amal Raj suggestion that WORK!!!!