How are the "Model parameters" derived from the "Module data" in a PV Array block?

12 vues (au cours des 30 derniers jours)

The PV Array block in Simulink has 5 model parameters that are not tunable. When selecting the "User-defined" model, these model parameters seem to be derived from the 8 module data parameters. Can you explain more about how these model parameters are calculated according to the module data?

Réponse acceptée

MathWorks Support Team
MathWorks Support Team le 22 Oct 2024
The 8 "Module data" parameters in the PV Array block define the physical characteristics and performance metrics of the PV module, while the 5 "Model parameters" are used in the mathematical equations that simulate the module's electrical behavior.
For a user-defined PV module, when the 7 tunable "Module data" parameters are provided (note that the "Maximum Power" parameter is not tunable), the initial 5 "Model parameters" are generated for the simulation. An optimization function is then triggered to iteratively minimize the error between the characteristic curves derived from the 7 module data parameters and the 5-coefficient dynamic model. The optimization adjusts the 5 model parameters at each step until the simulated model closely aligns with the physical PV Array module.

Plus de réponses (0)

Catégories

En savoir plus sur Simscape Electrical dans Help Center et File Exchange

Produits


Version

R2024b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by