rated_torque not matching desired torque for IPMSM
6 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Hi Community,
I am refering this example https://in.mathworks.com/help/mcb/gs/foc-pmsm-using-hall-sensor-example.html .
- 'rated_torque' not matchning with desired torque after entering motor, inverter parameters. I am getting 2 Nm torque, but my expedted torque is 21Nm. How can I get desired torque?
- What is difference between 'pmsm.T_rated' and 'rated_torque' ?
Below is the Torque_speed graph for referance.
Thanks in Advance.
1 commentaire
Réponses (1)
VBBV
le 6 Déc 2024
Hi
From the reference graph you have, it seems the value you get for rated torque is correct. It's about 2.25 Nm. If you look at the power vs speed graph, the nominal power is about 595 W at 0.25 x 10^4.
If you calculate torque from power and speed you would get 2.25 Nm which is correct. There is NO difference between pmsm.T_rated' and 'rated_torque'