Problem after Converting the simulink model from R2024a to R2022b

6 vues (au cours des 30 derniers jours)
Vangala
Vangala le 9 Déc 2024
Réponse apportée : Vangala le 11 Fév 2025
I have a Simulink model (1D model using simscape blocks) in R2024a. I have to generate .exe file. Bz of situation, I wanted to degrade my model to R2022b. But when I run that model in R2022b, it causing multiple errors. I have rearranged the simscape blocks there according to R2022b. Even then this error persists. What are the precautions should be taken to eliminate this error?
  2 commentaires
Yukthi S
Yukthi S le 9 Déc 2024
Can you share the error message and the simulink model for better understanding?
Vangala
Vangala le 9 Déc 2024
Error " No of variables exceeds no of equations"

Connectez-vous pour commenter.

Réponse acceptée

Vangala
Vangala le 11 Fév 2025
Hi guys,
Thanks for anwering the question above. I had solved it myself.
In R2022b, When you use pressure and temperature sensor, connect its A to main stream flow and B to the absolute reference. Remove unwanted sensors in the whole loop.
This method solved the issue: "No of variables greater than no. of equations".

Plus de réponses (1)

Saurabh
Saurabh le 11 Déc 2024
Modifié(e) : Saurabh le 20 Déc 2024
This seems to be a possible bug try running the model using 'sim(bdroot)' and then clicking the hyperlinks which appear in the command window.
I hope this helps