xdc_focus_times for 2D array transducer in Field2
6 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Hi,
I'm trying to simulate time delays for each element in a 2D array transducer using field2 program.
I only managed to use the xdc_focus_times function to add delays for 1D array and not 2D.
Is there any way to do it for 2D transducer created with xdc_2d_array() ?
thank you in advance.
0 commentaires
Réponses (1)
karthik kumar k
le 9 Fév 2025
To set delays for a 2D transducer array in Field II, calculate the delays for each element and use xdc_focus() to apply the focus. Here's how:Steps:
1. Create the 2D Array:
Nx = 16; Ny = 16; % Number of elements
width = 0.5e-3; height = 0.5e-3; % Element dimensions
kerf_x = 0.1e-3; kerf_y = 0.1e-3; % Spacing
focus = [0, 0, 0.04]; % Focus point
Th = xdc_2d_array(Nx, Ny, width, height, kerf_x, kerf_y, focus);
2. Calculate Delays:
c = 1540; % Speed of sound (m/s)
[elem_x, elem_y] = ndgrid(...
linspace(-Nx/2, Nx/2-1, Nx) * (width + kerf_x), ...
linspace(-Ny/2, Ny/2-1, Ny) * (height + kerf_y));
element_positions = [elem_x(:), elem_y(:), zeros(numel(elem_x), 1)];
delays = sqrt(sum((element_positions - focus).^2, 2)) / c;
3. Assign Delays:
xdc_focus(Th, 0, delays);
0 commentaires
Voir également
Catégories
En savoir plus sur Ultrasound Imaging dans Help Center et File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!