Matlab function in Simulink exhibiting slow reaction time

6 vues (au cours des 30 derniers jours)
I have a function block within my simulink file. It reads a "current" value, and compares it to a reference value.
If the value is higher than ref is turns off one input, and the next time the function block is called the expected behavior is that it should turn off a additional input if the value is still higher than reference.
For some reason it only turns off additional inputs every ~1700 seconds or so. Simulation time is 24h. I do not really see what could cause this. It behaves as expected, but as if it is only called every 1700 seconds.
There is a delay block at the output of the funciton, that then feeds back - giving the current status of all inputs. It is set to a delay of 1.

Réponse acceptée

Fangjun Jiang
Fangjun Jiang le 6 Mar 2025
Modifié(e) : Fangjun Jiang le 6 Mar 2025
I must know this. 1700 seconds is roughly 1/50 of the simulation time (24 hours). It is the default setting. It must mean that you didn't specify the simulation step size. One step of simulation of your model is about 1700 seconds. That is the reason.
Specify a reasonable step size and you will see the effect.
  1 commentaire
Lillebror Sagmen-Andersson
Aha! There we have it! I did not realize the deafult was 1/50. Thanks for the help :)

Connectez-vous pour commenter.

Plus de réponses (0)