Info
Cette question est clôturée. Rouvrir pour modifier ou répondre.
microphone plot response documentation results different from execution results
4 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
I have taken an example program from MATLAB documentation as below (phased array)
freq = [500 1000];
hmic = phased.CustomMicrophoneElement(...
'PolarPatternFrequencies',freq);
hmic
hmic.PolarPattern= mag2db([...
0.5+0.5*cosd(hmic.PolarPatternAngles);...
0.6+0.4*cosd(hmic.PolarPatternAngles)]);
plotResponse(hmic,freq,'Format','Polar');
ha = phased.ULA('NumElements',4,'ElementSpacing',0.5,...
'Element',hmic);
figure;
plotResponse(ha,freq,340,'Format','Polar')
ha = phased.ULA('NumElements',4,'ElementSpacing',0.5,...
'Element',hmic);
figure;
plotResponse(ha,freq,340,'Format','Polar')
When I run the results are different in the sense that the polar angle measurement is in reverse order. In the documentation plots, the angle measurement is positive for clockwise where as I get positive for anticlockwise. Why is this?
Is the documentation to be updated?
0 commentaires
Réponses (1)
Honglei Chen
le 27 Mai 2015
The documentation is not up to date. Thanks for catching that. The plot is now counter clockwise so the positive angles are above 0 degrees and negative angles are below 0 degrees. This seems to match people's expectation better.
0 commentaires
Cette question est clôturée.
Voir également
Produits
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!