Issues with Embedded Coder support package for infineon Aurix TC4
Afficher commentaires plus anciens
Hello my fellow Aurix TC4 enjoyer,
i have trouble configuring the Hardware Setup. When validating the TC4 iLLD it matlab returns no error but when clicking on next, an error message appears:
Unable to load screen matlab.hwmgr.internal.hwsetup.Confirm TPInstallation Details: 3P ILLD for TC4x family not registered. Not possible. Internal error!
What can i do here? The installation of the iLLD seems to have worked correctly.
Réponses (1)
Rajasekhar
le 28 Avr 2026 à 10:20
0 votes
Hi Frederik,
You might be encountering this issue due to either restricted folder access or incorrect extraction of the iLLD files.
You can try the following steps to validate the TC4 iLLD installation path:
- Make sure the “iLLD” zip folder path does not require Admin access. For example, do not keep the iLLD zip folder in "C:\Program Files."
- The iLLD zip folder consists of multiple zip folders. Extract the first layer of the zip folder only and no need to extract the inner zip folders.