Can any one give me the idea that how can I design a load in a grid integrated PV system which changes after 1 sec of simulation starts.
1 vue (au cours des 30 derniers jours)
Afficher commentaires plus anciens
I have used a 2 MW load in my simulation. I want to run my simulation in such a way that 1 sec after the simulation starts the used load (i.e 2 MW) changes to 4 MW. If any body know this, kindly help me to do the same.
0 commentaires
Réponses (1)
Murali Krishna
le 24 Juin 2015
If you are simulating the load on the system using RLC branch available in the Simulink tool box, you can change the load by using a circuit breaker block and step block. Give the step time as 1 sec so that the transition from 0 to 1 closes the circuit breaker and adds additional load on the system
0 commentaires
Voir également
Catégories
En savoir plus sur Switches and Breakers dans Help Center et File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!