why type 2 FIR filter cannot be used to design high pass filter?
Afficher commentaires plus anciens
can anybody explain why type 2 FIR filter cannot be used to design high pass filter?
Réponses (1)
Honglei Chen
le 14 Jan 2016
0 votes
This is because for Type II FIR, there is a zero corresponding to Nyqiust rate, i.e., half sampling frequency. However, a high pass filter needs to let that component pass, so it cannot be used for a high pass filter.
2 commentaires
pavan sunder
le 14 Jan 2016
Honglei Chen
le 14 Jan 2016
You can think of the unit circle as the frequency axis. Starting from (1,0), which corresponds to the 0 frequency. If you travel along the circle and come back to the starting point, it corresponds to Fs. Therefore, half the circle is just Fs/2, which corresponds to z = -1. HTH