why type 2 FIR filter cannot be used to design high pass filter?
5 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
can anybody explain why type 2 FIR filter cannot be used to design high pass filter?
0 commentaires
Réponses (1)
Honglei Chen
le 14 Jan 2016
This is because for Type II FIR, there is a zero corresponding to Nyqiust rate, i.e., half sampling frequency. However, a high pass filter needs to let that component pass, so it cannot be used for a high pass filter.
2 commentaires
Honglei Chen
le 14 Jan 2016
You can think of the unit circle as the frequency axis. Starting from (1,0), which corresponds to the 0 frequency. If you travel along the circle and come back to the starting point, it corresponds to Fs. Therefore, half the circle is just Fs/2, which corresponds to z = -1. HTH