Simulink MPC Designer ZOH FOH Error
Afficher commentaires plus anciens
I am trying to design an MPC controller using the simulink controller toolbox. Whenever I try to make the MPC sample time less that 1, I get the following error: "The "zoh" and "foh" methods cannot be used for discrete models with poles near z=0" Could someone please explain what the error means and how I fit my controller? Thanks
2 commentaires
Steven
le 20 Mar 2020
Did you ever fix this?
Jordan Olson
le 1 Juil 2020
I'm also having this issue, but changing the sample time in the MPC doesn't fix it.
Réponses (1)
dekun wang
le 18 Mai 2021
0 votes
poles in discrete domain near z=0 means poles in continuous domain tending to -infinite which means your system's natural frequency is infinitely large. It cannot be true for any systems. So my suggestion would be to double check your plant model.
Catégories
En savoir plus sur Controller Creation dans Centre d'aide et File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!