I am working on the simulation of a Solid State Transformer.It has three modules- the PWM rectifier, the Dual Active Bridge Converter and the Inverter.The modules work well individually but the input current gets distorted with the whole system.Why??

20 vues (au cours des 30 derniers jours)
When I am synchronising the PWM Rectifier with the Dual Active Bridge Converter and the Inverter, the current becomes highly distorted. However, the output current and voltage as well as the intermediate stage voltages are perfect as per my design. I have tried several PWM techniques- the abc-dq-abc transform technique, the Direct Power Control technique. However every time it is the input current which gets distorted.

Réponses (2)

Taimur Zaman
Taimur Zaman le 18 Mai 2018
Dear Partha Sarthy, As per my knowledge, your input current is distorting because that you are using very high frequency transformer. Since due to very high switching frequency, the energy residues in the transformer winding, and so a huge current start flowing which means simply shorted. You need to design a good series inductor for your dual active bridge, so that during switching, the energy transfers from transformers to inductor and ZVS phenomeno occur.

Komal Autkar
Komal Autkar le 18 Mai 2018
I am working on MATLAB/simulink model of Solid State Transformer interfaced Wind Energy Conversion System as my post graduate dissertation work. Can anyone send me the simulation model of solid state transformer?
  6 commentaires
Komal Autkar
Komal Autkar le 16 Juil 2018
Yes..Can you share an email id? sothat I can contact you.

Connectez-vous pour commenter.

Communautés

Plus de réponses dans  Power Electronics Control

Catégories

En savoir plus sur Specialized Power Systems dans Help Center et File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by