Unable to access Polyspace Metrics http address
2 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Hi I have Polyspace Metrics running on a network server and am trying to connect on a client node. It can find the address when I enter in the IP and port to the Server Settings in Bug Finder, but when I try to access the server at http://IPADDR:8080/ I get 'This page can't be displayed.'
I see in the documentation something about changing a variable in a tomcat folder in the Metrics Server's %APPDATA% folder, but there is no tomcat folder, just a locks folder and a log file.
0 commentaires
Réponses (1)
Alexandre De Barros
le 22 Nov 2016
Hello Dylan,
For the tomcat folder, I guess that you are referring to this page: https://www.mathworks.com/help/codeprover/gs/set-up-polyspace-metrics.html#bt_7wzm-5
Did you see any error message when you clicked the Start Daemon button, as described here? : https://www.mathworks.com/help/codeprover/gs/set-up-polyspace-metrics.html#bt_7xa3
Please note that you can see the Metrics log (for potential errors) by launching the 'Metrics and Remote Server Settings' interface and by clicking the button 'View Log'.
Moreover, are you able to access the Metrics webpage by the address http://IPADDR:8080/ on the Metrics server itself?
Regards
Alexandre