simscapepower and other block connection error
Afficher commentaires plus anciens
I am trying to create a model using simscape but the unable to make connections between current measurement block to another block. I tried with Simulink ps converter but still having the same problem.For detailed understanding, I attached the image file

Réponses (1)
Andrew Schenk
le 28 Nov 2016
0 votes
You cannot directly interface Simscape Power Systems Specialized Technology blocks with Simscape blocks. Consider replacing the Breaker block with the Simscape block https://www.mathworks.com/help/physmod/sps/ref/singlephasecircuitbreaker.html which will allow a direct connection.
Alternatively, use the following example to show how Specialized Technology blocks can be connected to Simscape blocks: https://www.mathworks.com/help/physmod/sps/powersys/ref/currentvoltagesimscapeinterface.html
1 commentaire
Yaser Arafat
le 29 Nov 2016
Catégories
En savoir plus sur Electrical Sensors dans Centre d'aide et File Exchange