I am trying to create a model using simscape but the unable to make connections between current measurement block to another block. I tried with Simulink ps converter but still having the same problem.For detailed understanding, I attached the image file

Réponses (1)

Andrew Schenk
Andrew Schenk le 28 Nov 2016
You cannot directly interface Simscape Power Systems Specialized Technology blocks with Simscape blocks. Consider replacing the Breaker block with the Simscape block https://www.mathworks.com/help/physmod/sps/ref/singlephasecircuitbreaker.html which will allow a direct connection.
Alternatively, use the following example to show how Specialized Technology blocks can be connected to Simscape blocks: https://www.mathworks.com/help/physmod/sps/powersys/ref/currentvoltagesimscapeinterface.html