My system consist of set of equations. How to implement PID controller for my system ?
2 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
How to make it closed loop ?
0 commentaires
Réponses (1)
Arkadiy Turevskiy
le 6 Déc 2016
In a simple case of a mass spring damper mx''+cx'+kx=F
convert system equations to a transfer function
m=1;c=1;k=1; %replace with your own values
plant=1/(m*s^2+c*s+k);
Now define a controller
C=5; %simple proportinal gain
C=pid(5,1); % PI compensator
Compute closed loop transfer function and plot step response:
CL=feedback(C*plant,1);
step(CL);
HTH.
0 commentaires
Voir également
Catégories
En savoir plus sur Classical Control Design dans Help Center et File Exchange
Produits
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!