Missing Signal Target Scope
Afficher commentaires plus anciens
Hello,
as described above a signal is not displayed numerically on the target pc running simulink realtime (R2015b). Others are displayed in the same scope.
If I try to read out the signal by command prompt (Matlab R2015b):
>> tg.getsignalidsfromlabel('dLambda1')
ans = 335
>> tg.getsignal(335)
Error using xpctarget.xpc/getsignal TargetPC1: Invalid Signal index
Additionally the signal index is higher than the number of signals. I would be a happy for a possible solution / short explanation what is going wrong here.
Thank you in advance.
Best regards Roman
Réponses (1)
Hari Desanur
le 12 Déc 2016
0 votes
You must make sure that the signal which you are trying to monitor is not virtual signal or a virtual bus. You may have to add a 'Gain' block to monitor that signal -
Catégories
En savoir plus sur Scopes and Data Logging dans Centre d'aide et File Exchange
Produits
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!