controlling manual switch through m-file
1 vue (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Krishnendu Mukherjee
le 13 Mar 2012
Commenté : Jon
le 28 Juil 2020
there in a manual switch,which can be altered during run time.now if i want to alter the switch through m-file command.what to do?
Réponse acceptée
Kaustubha Govind
le 13 Mar 2012
It looks like this should work
set_param('path/to/block', 'sw', '0')
set_param('path/to/block', 'sw', '1')
I found the names of the block parameters using this command, and just picked the one that seemed likely:
>> get_param(gcb, 'DialogParameters') % select the block first with the mouse
1 commentaire
Jon
le 28 Juil 2020
In version 2020A, for a manual switch (assuming it has just been selected)
get_param(gcb,'DialogParameters')
returns only the parameters varsize and SampleTime.
It seems that this 'sw' parameter does still give the switch postion, but where is this documented?
In particular is there a command similar to get_param(gcb,'DialogParameters') that would list this type of "hidden" parameter, or is there somewhere it would be listed in any of the documentation? I couldn't find it.
Thanks
Plus de réponses (0)
Voir également
Catégories
En savoir plus sur Simulink Functions dans Help Center et File Exchange
Produits
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!