Alternative to change simscape parameters during run-time

1 vue (au cours des 30 derniers jours)
Alicia Roder
Alicia Roder le 15 Mar 2017
Modifié(e) : Alisha Schor le 20 Mar 2017
As far as I can see it is not possible to change Simscape parameters during runtime. Is this correct? In my Simulation I have to turn a pump in a hydraulic system on and off depending on the pressure within the system. What is the best way to realize this? Thank you very much!

Réponse acceptée

Alicia Roder
Alicia Roder le 20 Mar 2017
For a fixed-displacement pump driven by a ideal angular velocity source the pump can be turned on and off via a simulink-PS converted output signal (e.g. 0 and 1) from Stateflow fed into the S-port of the ideal angular velocity source.

Plus de réponses (1)

Alisha Schor
Alisha Schor le 20 Mar 2017
Modifié(e) : Alisha Schor le 20 Mar 2017