National Instruments USB 6210 does't work in Simulink, Analog Input Block
3 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Uriel Jost
le 25 Avr 2017
Modifié(e) : Prashant Arora
le 28 Avr 2017
Hallo,
i try to read out signals of NI USB 6210 with Simulink "Analog Input Block" but I can't find my device in the list of the Block Parameters (Data acquisition board-->Istall new board). Boards like PCI 6250 are listet and many more of the National Instruments boards but no USB Board.
I have installed Data Acquisition Toolbox and NI-DAQmx (nidaqmx.mlpkginstall, https://de.mathworks.com/hardware-support/nidaqmx.html). The description of the supported hardware says that USB-6210 is supported. And reading singnals with matlab useing e.g. daq.createSession('ni');... works great. I use Matlab R2015b 64bit. So please can you help me? Kind regards Uriel
0 commentaires
Réponse acceptée
Prashant Arora
le 28 Avr 2017
Modifié(e) : Prashant Arora
le 28 Avr 2017
Hi Uriel,
In R2015b, Data Acquisition Toolbox Simulink Blocks support only Legacy Interface, that too on 32-bit MATLAB. You can refer to the following link for further information
0 commentaires