- By area vs. opening table — Provide tabulated data of valve openings and corresponding valve passage areas. The passage area is determined by one-dimensional table lookup. You have a choice of two interpolation methods and two extrapolation methods.
- By pressure-flow characteristic — Provide tabulated data of valve openings, pressure differentials, and corresponding flow rates. The flow rate is determined by two-dimensional table lookup. You have a choice of two interpolation methods and two extrapolation methods.
How to parameterize hydraulic valve with given manufacturer data sheet current vs flow rate?
1 vue (au cours des 30 derniers jours)
Afficher commentaires plus anciens
sanjeev kumar
le 18 Juil 2017
Commenté : Sebastian Castro
le 19 Juil 2017
Dear All How do i parameterize the 2 way and 3 way directional valve with given manufacturer data sheet current vs flow rate?
0 commentaires
Réponse acceptée
Sebastian Castro
le 18 Juil 2017
The directional valve blocks have a Model Parameterization option in their dialogs. Two of those values let you enter your own data from, e.g., a datasheet.
From the documentation:
- Sebastian
2 commentaires
Sebastian Castro
le 19 Juil 2017
Current? As in electric current, probably for a valve solenoid or something?
Is that then current vs. flow rate for a specific pressure? Because if so, you can probably back out the valve area as a function of input current...
Plus de réponses (0)
Voir également
Catégories
En savoir plus sur Upgrading Hydraulic Models to Use Isothermal Liquid Blocks dans Help Center et File Exchange
Produits
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!