Simulink Linear Analysis Pole/Zero Plots

5 vues (au cours des 30 derniers jours)
Andres
Andres le 15 Août 2017
Commenté : Sebastian Castro le 16 Août 2017
Attached is the Simulink file I'm having problems with. I have this system controlled by a PID controller which gives me the desired response on 'Scope1'. Now I want to do some plots using "Analysis -> Control Design -> Linear Analysis...".
Here I get my bode and step responses plot, but when I go to the "I/O Pole/Zero Map" all the poles and zeros are on the right side (real positive values) which means the system is unstable and it seems to be contradictory from the step and bode plot that shows an stable system. Am I missing or misinterpreting anything? Here are the bode and step plots I get:
And this is the I/O Pole/Zero Map:

Réponse acceptée

Sebastian Castro
Sebastian Castro le 15 Août 2017
Modifié(e) : Sebastian Castro le 15 Août 2017
Based on the staircase step response, looks like your system is discrete.
This means that stability is inside the unit circle (circle of radius 1), which it is :)
- Sebastian
  2 commentaires
Andres
Andres le 15 Août 2017
Hooo ok, so in discrete systems everything inside the circle is stable? Do you have any resource where I can read about this? Thank you Sebastian :)

Connectez-vous pour commenter.