Using fread to read streaming binary data from ethernet using Instrument Control Toolbox
3 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
My data are uint8 format. The documentation for fread seems to imply that the "precision" argument can set the output format of fread. But if I try to use precision='*uint8' or 'uint8=>uint8' I get an error. The default output is double, which takes too much memory. I've been using
Output=uint8(fread(TcpipObj,SIZE,'uint8'))
which works, but I'm guessing this generates a large array of doubles then converts to uint8.
My instrument streams data until the buffer is full, so I set up TcpipObj.InputBufferSize to pull in the data I need. I then set SIZE to the same value. I'd like to pull in 40 MB or so, but get a java heap memory error.
Suggestions?
Jim
4 commentaires
Réponses (1)
Voir également
Catégories
En savoir plus sur Instrument Control Toolbox dans Help Center et File Exchange
Produits
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!