Optimal Power Flow by Vector PSO: I need add generate at bus 10 ( 30MW).What is the change in this code?

5 vues (au cours des 30 derniers jours)
Yasir Ghazi
Yasir Ghazi le 5 Mar 2018
Clôturé : Sabin le 19 Déc 2024
clear;
clc;
% IEEE 30-BUS TEST SYSTEM (American Electric Power)
% Bus Bus Voltage Angle ---Load---- -------Generator----- Injected
% No code Mag. Degree MW Mvar MW Mvar Qmin Qmax Mvar
global basemva busdata linedata gencost Pdt LF
basemva=100;
busdata=[1 1 1.06 0.0 0.0 0.0 0.0 0.0 0 0 0
2 2 1.043 0.0 21.70 12.7 40.0 0.0 -40 50 0
3 0 1.0 0.0 2.4 1.2 0.0 0.0 0 0 0
4 0 1.06 0.0 7.6 1.6 0.0 0.0 0 0 0
5 2 1.01 0.0 94.2 19.0 0.0 0.0 -40 40 0
6 0 1.0 0.0 0.0 0.0 0.0 0.0 0 0 0
7 0 1.0 0.0 22.8 10.9 0.0 0.0 0 0 0
8 2 1.01 0.0 30.0 30.0 0.0 0.0 -10 60 0
9 0 1.0 0.0 0.0 0.0 0.0 0.0 0 0 0
10 0 1.0 0.0 5.8 2.0 0.0 0.0 -6 24 19
11 2 1.082 0.0 0.0 0.0 0.0 0.0 0 0 0
12 0 1.0 0 11.2 7.5 0 0 0 0 0
13 2 1.071 0 0 0.0 0 0 -6 24 0
14 0 1 0 6.2 1.6 0 0 0 0 0
15 0 1 0 8.2 2.5 0 0 0 0 0
16 0 1 0 3.5 1.8 0 0 0 0 0
17 0 1 0 9.0 5.8 0 0 0 0 0
18 0 1 0 3.2 0.9 0 0 0 0 0
19 0 1 0 9.5 3.4 0 0 0 0 0
20 0 1 0 2.2 0.7 0 0 0 0 0
21 0 1 0 17.5 11.2 0 0 0 0 0
22 0 1 0 0 0.0 0 0 0 0 0
23 0 1 0 3.2 1.6 0 0 0 0 0
24 0 1 0 8.7 6.7 0 0 0 0 4.3
25 0 1 0 0 0.0 0 0 0 0 0
26 0 1 0 3.5 2.3 0 0 0 0 0
27 0 1 0 0 0.0 0 0 0 0 0
28 0 1 0 0 0.0 0 0 0 0 0
29 0 1 0 2.4 0.9 0 0 0 0 0
30 0 1 0 10.6 1.9 0 0 0 0 0];
% Line code % Bus bus R X 1/2 B = 1 for lines % nl nr p.u. p.u. p.u. > 1 or < 1 tr. tap at bus nl linedata=[1 2 0.0192 0.0575 0.02640 1 1 3 0.0452 0.1852 0.02040 1 2 4 0.0570 0.1737 0.01840 1 3 4 0.0132 0.0379 0.00420 1 2 5 0.0472 0.1983 0.02090 1 2 6 0.0581 0.1763 0.01870 1 4 6 0.0119 0.0414 0.00450 1 5 7 0.0460 0.1160 0.01020 1 6 7 0.0267 0.0820 0.00850 1 6 8 0.0120 0.0420 0.00450 1 6 9 0.0 0.2080 0.0 0.978 6 10 0 .5560 0 0.969 9 11 0 .2080 0 1 9 10 0 .1100 0 1 4 12 0 .2560 0 0.932 12 13 0 .1400 0 1 12 14 .1231 .2559 0 1 12 15 .0662 .1304 0 1 12 16 .0945 .1987 0 1 14 15 .2210 .1997 0 1 16 17 .0824 .1923 0 1 15 18 .1073 .2185 0 1 18 19 .0639 .1292 0 1 19 20 .0340 .0680 0 1 10 20 .0936 .2090 0 1 10 17 .0324 .0845 0 1 10 21 .0348 .0749 0 1 10 22 .0727 .1499 0 1 21 22 .0116 .0236 0 1 15 23 .1000 .2020 0 1 22 24 .1150 .1790 0 1 23 24 .1320 .2700 0 1 24 25 .1885 .3292 0 1 25 26 .2544 .3800 0 1 25 27 .1093 .2087 0 1 28 27 0 .3960 0 0.968 27 29 .2198 .4153 0 1 27 30 .3202 .6027 0 1 29 30 .2399 .4533 0 1 8 28 .0636 .2000 0.0214 1 6 28 .0169 .0599 0.065 1]; %generator cost coefficients % bus no a b c Pg(min) Pg(max) gencost = [1 0.00375 2 0 50 200; 2 0.0175 1.75 0 20 80; 5 0.0625 1 0 15 50; 8 0.0083 3.25 0 10 35; 11 0.025 3 0 10 30; 13 0.025 3 0 12 40]; %Lineflow limits MVA LF=[130 130 65 130 130 65 90 70 130 32 65 32 65 65 65 65 32 32 32 16 16 16 16 32 32 32 32 32 32 16 16 16 16 16 16 65 16 16 16 32 32]; Pdt=283.4;
l=gencost(2:6,5)'; u=gencost(2:6,6)'; ran=[l' u']; nnn=length(gencost(:,1))-1; Pdef = [20 200 20 2 2 0.9 0.4 1500 1e-6 5000 NaN 0 0]; [OUT]=pso_Trelea_vectorized('opf2',nnn,1,ran,0,Pdef); out=abs(OUT); P1=out(1:nnn) [F1 P VV]=opf2(P1') TL=sum(P)-Pdt
  1 commentaire
Yasir Ghazi
Yasir Ghazi le 5 Mar 2018
https://www.mathworks.com/matlabcentral/fileexchange/46002-optimal-power-flow-by-vector-pso

Réponses (0)