Goto/From connections cannot cross nonvirtual subsystem boundaries. The only exception is when a goto is connected to a state output port

174 vues (au cours des 30 derniers jours)
Hi all,
I have goto Tags placed within a Triggered subsystem, with their corresponding from Tags in the highest level of the simulink model.
However, I received the error 'Goto/From connections cannot cross nonvirtual subsystem boundaries. The only exception is when a goto is connected to a state output port'.
May I know how can I go about solving this problem?
Any help is greatly appreciated!
Best Regards, Rachel
  1 commentaire
Zangdaarr
Zangdaarr le 6 Mai 2016
Modifié(e) : Zangdaarr le 6 Mai 2016
Goto/From are a pain in the ass. Do not use them, never. Especially in their "global" form, which is terrible.
Goto/From are just a bypass for when people are not capable to make clean model, same apply with C/C++ and global variables.

Connectez-vous pour commenter.

Réponses (1)

Guy Rouleau
Guy Rouleau le 25 Mai 2012
The error message is clear... don't place GoTo block inside the triggered subsystem and corresponding From block outside.
Use normal signals instead to exist the triggered subsystem.
An atomic subsystem must execute everything that is inside in one unit. And GoTo and From are also like one unit. So making one cross the other is incompatible.
Depending on the sample time involved, if you really do not want to see a signal line, maybe global Data Store Read and Write could help.
  2 commentaires
rach
rach le 26 Mai 2012
Hi Rouleau, thanks for the reply.
I tried to follow your suggestion on using Data Store Read and Write, and received the following error:
Invalid setting for input port dimensions of 'microgridInput_dataRW/VSC Controller (Station 1)/Anti-aliasing Filters/Demux5'. The dimensions are being set to 1. This is not valid because the total number of input and output elements are not the same
May I know how should I go about solving this problem? Thank you so much for your help, I really appreciate it.
Cheers,
Rach
Kevin
Kevin le 14 Déc 2015
Just use normal connection. Don't bother using goto or read/write blocks . This make your model harder to read, but if you want to pass signal inside triggered/function call subsystem, you got no other choice. Good luck

Connectez-vous pour commenter.