Effacer les filtres
Effacer les filtres

if loop inside matlab function ----- i dont understand why this is not working

1 vue (au cours des 30 derniers jours)
Ramu Nair R
Ramu Nair R le 22 Avr 2018
Modifié(e) : Ramu Nair R le 8 Sep 2018
function y = fcn(u)
if(u>0.7) && (u<0.71)
y=1;
end
It gives error when put inside my simulink simulation:
Output argument 'y' is not assigned on some execution paths.
Function 'MATLAB Function' (#38.9.10), line 1, column 10:
"y"
Launch diagnostic report.
Component:MATLAB Function | Category:Coder error
Errors occurred during parsing of MATLAB function 'MATLAB Function'
  11 commentaires
Stephan
Stephan le 22 Avr 2018
Modifié(e) : Walter Roberson le 8 Sep 2018
function y = fcn(u)
y=0;
if(u>0.7) && (u<0.71) && y=0
y=1;
end
This could help to latch i guess
Ramu Nair R
Ramu Nair R le 8 Sep 2018
Modifié(e) : Ramu Nair R le 8 Sep 2018
function y = fcn(u)
y=0;
if ((u>0.7) && (u<0.71) && y=0)
y=1;
end
I am getting the following error: Simulink cannot determine sizes and/or types of the outputs for block 'MATLAB Function' due to errors in the block body, or limitations of the underlying analysis. The errors might be inaccurate. Fix the indicated errors, or explicitly specify sizes and/or types for all block outputs.

Connectez-vous pour commenter.

Réponses (1)

Ameer Hamza
Ameer Hamza le 22 Avr 2018
Modifié(e) : Ameer Hamza le 23 Avr 2018

Here is a event based solution to latch the value. The solution use if block and if action subsystem to latch the output once a certain condition is met. I used the clock as the input and the if condition becomes true between 20 to 21 seconds but output remains 1 after 20 seconds.

The Simulink model file is also attached.

  13 commentaires
Walter Roberson
Walter Roberson le 8 Sep 2018
Making init optional is not feasible for Simulink use. You would need to disable a port by disconnecting it, or you would need to use enabled subsystems that turned off an input (and I do not know how Simulink is defined to behave in that case.)
Once placed and connected, any one Simulink block is expected to always be called with the same number of inputs.
Ramu Nair R
Ramu Nair R le 8 Sep 2018
Modifié(e) : Ramu Nair R le 8 Sep 2018
Thanks a lot, Roberson and all others who contributed to the discussion. Now, it is doing what it is supposed to do !!