Comparing output of different simulink model versions - Simulink Test

1 vue (au cours des 30 derniers jours)
Varunjith Vijayan
Varunjith Vijayan le 15 Mai 2018
Modifié(e) : Deb Schwartz le 24 Sep 2024
Is there any method to compare the output of different model versions using Test manager? I have several output signals which may change according to the modifications on the model. I would like to get to know the changes in the output signals for different test harness. Is there any possibility on the Test manager?
  1 commentaire
TAB
TAB le 15 Mai 2018
How about including both model in test harness master model using Model Reference block, execute the test and compare result.

Connectez-vous pour commenter.

Réponse acceptée

Rong Mi
Rong Mi le 22 Mai 2018
Hi,
If you want to compare the results from two test cases, you can use equivalence test case in Test Manager. Please see the following link as a reference. https://www.mathworks.com/help/sltest/examples/test-two-simulations-for-equivalence.html
If you want to use one test result as a baseline and compare several test cases' results to this baseline result, you can use baseline test case in Test Manager. Please see the following link as a reference. https://www.mathworks.com/help/sltest/ug/set-up-a-baseline-test-case.html
  1 commentaire
Deb Schwartz
Deb Schwartz le 24 Sep 2024
Modifié(e) : Deb Schwartz le 24 Sep 2024
For the link in the first paragraph above about comparing two test cases, see this documention instead: