Effacer les filtres
Effacer les filtres

issue in running PIL with TI c2000

6 vues (au cours des 30 derniers jours)
Chandana Vishwanatha
Chandana Vishwanatha le 11 Juil 2018
Hello evryone i am working with Buck boost_int32_PIL from TI F28377s/TARGET there is no error but when i started the PIL I got : The timeout of 10 seconds for receiving data from the rtiostream interface has been exceeded. There might be multiple reasons for this failure. You should: (a) Check that the target hardware configuration is correct, for example, check that the byte ordering is correct. (b) Confirm that the target is running. (c) Consider the possibility of application run-time failures (e.g. divide by zero exceptions, incorrect custom code integration, etc.).
Note (c): To identify possible reasons for the run-time failure, consider using SIL, which supports signal handlers and debugging. If you cannot find a solution, consider using the method setTimeoutRecvSecs of rtw.connectivity.RtIOStreamHostCommunicator to increase the timeout value. Component:Simulink | Category:Modelerror Output argument "lSections" (and maybe others) not assigned during call to "coder.profile.ExecutionTime/get.Sections". Component:Simulink | Category:Modelerror
  1 commentaire
Li Wei
Li Wei le 26 Juil 2018
same issue happens on me. Anyone can help?

Connectez-vous pour commenter.

Réponses (3)

Chandana Vishwanatha
Chandana Vishwanatha le 27 Juil 2018
Modifié(e) : Chandana Vishwanatha le 27 Juil 2018
Hi Li Wei, I was able to solve the issue. There was a problem with the settings in Hardware configuration.Make sure you have selected the correct SCI pins and check the baud rate. F28377s launchpad uses GPIO 84 and 85 for SCIA. If you are using both ccs and matlab at a time. Close ccs and restart your system. Make sure you run only matlab and not ccs.
  3 commentaires
Chandana Vishwanatha
Chandana Vishwanatha le 31 Juil 2018
Hi Li Wei, there is a jumper for RX pin in the F28335 controlcard. Make sure you have closed J9 jumper.
Milovan
Milovan le 9 Fév 2023
Modifié(e) : Milovan le 9 Fév 2023
Had the same issue. I closed J9 jumper, but also turned off SW1 on the control card (F28335). Now it's working.

Connectez-vous pour commenter.


xuejie wu
xuejie wu le 6 Oct 2018
The same issue to you,did you solve it?
  1 commentaire
Chandana Vishwanatha
Chandana Vishwanatha le 8 Oct 2018
yes I did solve it

Connectez-vous pour commenter.


maxhuangkun
maxhuangkun le 2 Déc 2018
Hello, I also have the same problem as. Hardware setup and communication are correct.The device I use is DSP28335。My port A is GPIO63 and GPIO62. I used USB to TTL to set GPIO29 and GPIO28 to SCIA. So there should be no jumper problems, but still have this problem? I don’t know much about TI’s DSP.
  1 commentaire
Aradhya Sambhu Satpathy
Aradhya Sambhu Satpathy le 28 Avr 2023
Hello everyone i am working with TI F20025c Launchpad TARGET. When I am doing the PIL simulation I got the following error: The timeout of 10 seconds for receiving data from the rtiostream interface has been exceeded. There might be multiple reasons for this failure. You should: (a) Check that the target hardware configuration is correct, for example, check that the byte ordering is correct. (b) Confirm that the target is running. (c) Consider the possibility of application run-time failures (e.g. divide by zero exceptions, incorrect custom code integration, etc.).
Note (c): To identify possible reasons for the run-time failure, consider using SIL, which supports signal handlers and debugging. If you cannot find a solution, consider using the method setTimeoutRecvSecs of rtw.connectivity.RtIOStreamHostCommunicator to increase the timeout value. Component:Simulink | Category:Modelerror Output argument "lSections" (and maybe others) not assigned during call to "coder.profile.ExecutionTime/get.Sections". Component:Simulink | Category:Modelerror

Connectez-vous pour commenter.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by