How to change frequency unit in plot of viewGoal function without using right click and properties dialog?

3 vues (au cours des 30 derniers jours)
Hi there,
does anyone know how to change the frequency unit in the plot generate by the viewGoal() function, e.g. for a tuning goal like TuningGoal.Tracking, without doing a right click and using the properties dialog? The default option is rad/second, but I'd like to have Hz as default. Is there a command I can use in my script calling the viewGoal() function to set the frequency unit automatically to Hz? Is seems there is not "plotoptions" like bodeplot has.
Best regards, Robert

Réponse acceptée

Arkadiy Turevskiy
Arkadiy Turevskiy le 29 Oct 2018
Modifié(e) : Arkadiy Turevskiy le 29 Oct 2018
Hi,
Try this:
gmax = frd([1 1 0.01],[0 1 100]);
Req = TuningGoal.MaxGain('du','u',gmax);
viewGoal(Req);
h=gcr;
setoptions(h,'FreqUnits','Hz');
Hope this helps.
Arkadiy Turevskiy
MathWorks