Simscape- Moist air error. Temperature at port B must be less than or equal to Maximum valid temperature.

90 vues (au cours des 30 derniers jours)
</matlabcentral/answers/uploaded_files/139526/emosit_air_model.PNG> Attached image is my basic model, why am i getting assertion error.
An error occurred while running the simulation and the simulation was terminated Caused by: ['moist_air/Solver Configuration']: At time 134.033551, one or more assertions are triggered. See causes for specific information. Temperature at port B must be less than or equal to Maximum valid temperature. The assertion comes from: Block path: moist_air/Controlled Volumetric Flow Rate Source (MA).
Temperature at port A must be less than or equal to Maximum valid temperature. The assertion comes from: Block path: moist_air/Pipe (MA)1.
Please someone can help me with this?emosit_air_model.PNG

Réponses (2)

SARA
SARA le 15 Fév 2023
Hello Sachin,
Could you please find a solution to this issue?
Thank you

Martin
Martin le 22 Jan 2019
Hello Sachin,
One possibility is that the constant flow rate is causing a pressure rise in the Constant Volume Chamber. As the system keep trying to push the same flow into the chamber, the compression accompanies a rise in system temperature. Eventually this reaches the maximum setting for the network.
Try looking at the logged data to see if you see such a phenomenon happening.
Martin

Catégories

En savoir plus sur Data Logging dans Help Center et File Exchange

Produits

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by