In my simulink simulation, initial value of a particular constant input is to be given by me. Later on the value is changed by the feedback signal.
The feedback signal is also constant(1x1) but changes with time. My question is is there a block for this particular condition.?

 Réponse acceptée

Dhanashree Mohite
Dhanashree Mohite le 7 Fév 2019

0 votes

As per my understanding, you want to use one constant value while initializing and afterwards the feedback value.
So, actually there are multiple ways. Below are some:
1. You can use unit delay block for feedback and use it’s initial condition property to set initial value.
2. You can also use triggered or enabled subsystem. You can set initial value for it’s output port. And then you can use any value as it’s input afterward.

Plus de réponses (1)

Anand Shirke
Anand Shirke le 11 Fév 2019

0 votes

Block Initial Condition works like charm!

Catégories

En savoir plus sur Modeling dans Centre d'aide et File Exchange

Produits

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by