Effacer les filtres
Effacer les filtres

Simulink integrator block initial conditions

3 vues (au cours des 30 derniers jours)
Raghuraman S
Raghuraman S le 5 Fév 2019
Commenté : Wang Tao le 24 Avr 2021
Hi, How does one specify initial conditions in simulink integrator block for times not t= 0 for example, y(3) =5;

Réponse acceptée

Fangjun Jiang
Fangjun Jiang le 5 Fév 2019
utilize the "External reset" (set as rising) and "Initial ocndition source" (set as external).
Compare clock with t=3 and make it as the "External reset" signal.
  4 commentaires
Fangjun Jiang
Fangjun Jiang le 23 Avr 2021
Compare Clock with Constant block (value is 3) using the Relational Operator block, the output is trur or false.
Wang Tao
Wang Tao le 24 Avr 2021
Thanks for the prompt reply! I can get the answer for the time after t=3 with the y(3)=5 now. But the problem is for the time earilier than 3 as t<3, is not correct.
I am handling some two point boundary value problem, which y(3)=5 is the end/ final condition. Is there any way to solve this.
It seems can change the initial setting of integrator through properties, but there are no final condition settings.

Connectez-vous pour commenter.

Plus de réponses (0)

Produits


Version

R2018b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by