park transformation for single phase

I am trying to transfer alpha abd beta with theta angle through park transformation ?
can anyone tell me what is the expected o/p form park transforation of the single phase conncected to grid ??
thanks

 Réponse acceptée

Arvind Sathyanarayanan
Arvind Sathyanarayanan le 22 Fév 2019

0 votes

To transform single phase voltages/currents to shift your voltage/current by 90 degrees and use this value as β and your original signal as α. This can then be converted to dq0 using library blocks available in simulink.
It is difficult to say what the expected output is without knowing about your system but, generally d and q are dc values.

Plus de réponses (1)

Arvind Sathyanarayanan
Arvind Sathyanarayanan le 25 Fév 2019

0 votes

Can you please attach the model (*.slx) and other files required to run it? Also, which version of Matlab are you using?

4 commentaires

Saif Zahran
Saif Zahran le 25 Fév 2019
my matlab verion R2018b. i sent u simple model. i just want to make sure that the output of park transformation should be DC constant value.
Arvind Sathyanarayanan
Arvind Sathyanarayanan le 25 Fév 2019
Saif, I do not have access to 2018b. Please see the model attached.
Arvind Sathyanarayanan
Arvind Sathyanarayanan le 28 Fév 2019
Saif,
You can phase shift using the complex phase shift block. I have never used this block as I don't have the toolbox.
The other option is to take the derivative of the sine signal. As you may know: and
Saif Zahran
Saif Zahran le 3 Mar 2019
i need to contact you please>

Connectez-vous pour commenter.

Communautés

Plus de réponses dans  Power Electronics Control

Catégories

En savoir plus sur Modeling dans Centre d'aide et File Exchange

Community Treasure Hunt