Error in 'bingwangnibia1/Subsystem/vo': Initialization commands cannot be evaluated.
Caused by:
  • PSB option menu block block (mask) does not have a parameter named 'NonlinearTolerance'
  3 commentaires
BAMMIDI RAVITEJA
BAMMIDI RAVITEJA le 21 Juin 2022
Delete Powergui block of new version and Replace with the block from your Installed Simulink library.It helped me.
Ali Hussein Numan
Ali Hussein Numan le 6 Juil 2024
Modifié(e) : Ali Hussein Numan le 6 Juil 2024
Yes replace the powergui block from your Installed Simulink library with the old one

Connectez-vous pour commenter.

Réponse acceptée

Andrew
Andrew le 25 Juin 2019
This looks like an issue with your specific model saved in a previous release being opened in a newer release. Reviewing our issue tracking database, I believe this issue has been fixed in MathWorks release R2019a. Please could you try opening your model in that version, and if it doesn't work please could you directly contact MathWorks support to provide them with your model.

Plus de réponses (1)

Yuan Ren
Yuan Ren le 11 Sep 2019
Drag a "powergui" from the library might help.
  2 commentaires
Xuanqi Zhao
Xuanqi Zhao le 2 Nov 2019
Yeah, I solved the same question in this way, thanks a lot.
Anton Shavin
Anton Shavin le 21 Août 2020
Same for me. Was one block from older Simulink version opened in the newer one