How to make a gate valve work in a hydraulic circuit?

1 vue (au cours des 30 derniers jours)
Austin Purvis
Austin Purvis le 18 Juin 2019
I am having trouble connecting a Gate Valve block to my hydraulic circuit. The hydraulic circuit uses a constant pressure source and passes flow through a 4-way directional valve to a motor (not pictured). I want to add a gate valve after the directional valve so that I can proportionally restrict flow.
The pipe is 19mm in diameter, however the constant signal that is being passed into the gate valve is 9 becuase I want to restrict the flow about 50%.
The pressure sensors before and after the gate valve indicate that there is no change in the flow. How do I fix this issue, so that the gate valve will proportionally restrict flow when I feed in different values?
  1 commentaire
omkar tulankar
omkar tulankar le 27 Nov 2020
Hi ,
I am also trying to use gate valve in gas system to delay the flow of gas flow in the circuit.
What I intend to do is start the gas flow between two ports in the circuit after the defined time delay with the help of valve .
But there's no effect seen on the output end.
I would like to know if there's any possible solution to this , "using gate valeve is gas systems ".
Thanks

Connectez-vous pour commenter.

Réponses (1)

Juan Sagarduy
Juan Sagarduy le 1 Déc 2020
Hi there Have you checked that the unit in the S-PS converter for the gate valve is set to mm? If not, Simscape believes it is 9m which is fully opening all the time. Br Juan

Catégories

En savoir plus sur Upgrading Hydraulic Models to Use Isothermal Liquid Blocks dans Help Center et File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by