Windowed FFT magnitude / leakage effect

1 vue (au cours des 30 derniers jours)
Tom Bedkowski
Tom Bedkowski le 5 Juil 2019
Modifié(e) : Tom Bedkowski le 1 Août 2019
Hello,
i am doing an windowed fft to get the magnitude by a frequency.
But the result of the magnitude is not the magnitude of the sampled summation of sinusfunction, which i defined.
This effect is the leakage effect and i heard about a correction factor to get the right magnitude from the windowed fft.
Thank you for help!

Réponses (1)

Samatha Aleti
Samatha Aleti le 17 Juil 2019
Hi,
You may calculate & apply Amplitude correction factor to compensate the leakage effect. Here is an example
N= 100;
w = hann(N);
% correction factor
Cf=length(w)/sum(w);
  1 commentaire
Tom Bedkowski
Tom Bedkowski le 1 Août 2019
Modifié(e) : Tom Bedkowski le 1 Août 2019
Thank you for help.
Yes that is the first correction which i done.
But there is a futher correction which depends on the specific window.
More in this hyperlink: Window Types