How to get steady state error values of a closed loop negative feedback system
6 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
How to get steady state error values of a closed loop negative feedback system using .m file command
for example,
s=tf('s');
G = 5/(s^2+2*s+25);
C = pidtune(G,'pid');
sys = feedback(C*G,1);
So now I want the values which is input to PID controller = steady state error values
How to do so ????
2 commentaires
izas
le 22 Nov 2019
Modifié(e) : izas
le 22 Nov 2019
I am not sure if you are still interested in the answer.
Y/R = CG/ (1+CGH); where H=1 in this case
(Error* CG)/R = CG/ (1+CGH);
Error (s) = R/ (1+CGH)
This is to say, the error is:
(one divided by (one plus the open loop)) multiplied by the reference.
If you need the final value in time, you apply the final value theorem (FVT). The FVT states:
lim e(t) = lim s * E(s)
t->inf s->0
Réponses (0)
Voir également
Catégories
En savoir plus sur Classical Control Design dans Help Center et File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!