Simulink trying to map struct to run-time parameter
21 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Marshall Trout
le 21 Août 2019
Commenté : Toshiyuki
le 3 Déc 2025 à 10:16
When attempting to run a function inside a Simulink model the simulation always fails due to the following error:
Unable to map parameter 'VarName' in 'FunctionName' to a run-time parameter. This parameter is an unsupported variable class such as a string, structure, cell, or an unsupported data type.
VarName is indeed a struct, but I do not understand why Simulink is attempting to make it a run-time parameter. VarName contains the initial conditions and online parameters used throughout the simulation. The Simulink model was built in 2013a and I am attempting to update it to run in 2017b. How can I prevent this error from occuring?
Thanks in advance.
0 commentaires
Réponse acceptée
Plus de réponses (1)
Noah Tang
le 28 Sep 2021
I was able to reproduce the same error message, and the comparison shows that the error happens when one field of my struct variable has an empty array as its value. Otherwise, the parameter passing process works just fine.