The Computed sample time

137 vues (au cours des 30 derniers jours)
Youssef Toubla
Youssef Toubla le 28 Août 2019
Hi,
i get this error:
The computed sample Time 2E-09 is not an integer multiple of the fixed step size 1E-08. the period, pulse width and phase delay parameters of this block need to be integer multiples of the fixed step size.
can anyone help
Reagrds
YT
  4 commentaires
sruthi kesav
sruthi kesav le 4 Mai 2020
Modifié(e) : sruthi kesav le 4 Mai 2020
Hi,
i get this error:
The computed sample time (1.25E-06) is not an integer multiple of the fixed step size (1E-05). The period, pulse width and phase delay parameters of this block need to be integer multiples of the fixed step size.
Can anyone help me.Thanks in advance.
Regards,
Shruthi.D
Fangjun Jiang
Fangjun Jiang le 4 Mai 2020
If the step size is 1 second, the sample time of any block could be 1, 2, 5, 10, etc. It can't be 2.3, 10.5 or smaller than 1 like 0.5, etc.
The easiest way for you is to change the step size to be 1.25E-6 if possible. You may have further issue though.

Connectez-vous pour commenter.

Réponse acceptée

Fangjun Jiang
Fangjun Jiang le 29 Août 2019
Based on your specification of Period (secs) and Pulse Width (% of period), Simulink calculated that the time incremental needs to be as small as 2E-09. But your fixed step size (1E-08) is larger. That is the error.
Double check your specification. Please note that if you want to specify 5% duty cycle, you should specify it as 5, not 0.05.

Plus de réponses (1)

Abhishek saini
Abhishek saini le 4 Mar 2022
The computed sample time (0.0004) is not an integer multiple of the fixed step size (0.0084). The period, pulse width and phase delay parameters of this block need to be integer multiples of the fixed step size