simulink control re entry atmosphere code
6 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Alessandro Vitiello
le 22 Oct 2019
Réponse apportée : Maadhav Akula
le 6 Nov 2019
Hi, I am trying to do this simulation, is a control of a re-entry vehicle. I have a nominal trajectory that comes from an optimization. and know I am trying to implement a control that follows this tracjectorie. but I have this error, I am sure that is very simple but I do not find the solution in the documentation, and so I can,t go on.
"Invalid structure-format variable specified as workspace input in 'entry/From Workspace'. If the input signal is a bus signal, the variable must be a structure of MATLAB time series objects. Otherwise, the variable must include 'time' and 'signals' fields, and the 'signals' field must be a structure with a 'values' field."
many thanks for your time and consideration.
kinds regards
0 commentaires
Réponse acceptée
Maadhav Akula
le 6 Nov 2019
When I loaded the given *.mat files the variables phin, rn, vn are actually stored as 1x1 struct, which is why errors are coming up.
So, after you load the *.mat files, run the following command:
phin = phin.mat;
rn = rn.mat;
vn = vn.mat;
Now, run your entry.slx model and also please change the phin’ to phin in your Simulink model.
Hope this helps!
0 commentaires
Plus de réponses (0)
Voir également
Catégories
En savoir plus sur Schedule Model Components dans Help Center et File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!