Effacer les filtres
Effacer les filtres

In the following simulink model solver configuration block is giving an error https://in​.mathworks​.com/matla​bcentral/f​ileexchang​e/48747-sm​art-grid

1 vue (au cours des 30 derniers jours)

Réponses (1)

Joel Van Sickel
Joel Van Sickel le 18 Août 2020
Hello Jagrati,
unfortunately, it seems this particular model is not being updated by it's owner, and there is not much we can do about that. The main issues with this model are numerous. one, it does not have all of it's components defined, and it needs to be brought through an upgrade advisor. Additionally, the simscape based solar cells should be replaced with the specialized power systems solar panel block. Mixing and matching thes technologies is possible, but requires more in depth knowledge of solver settings than if you stick to a single technology. Since the majority of this model is specialized power systems, it is easiest to replace the solar array. The solvers hould be set to ode23tb as well, since ode45 will provide the wrong results.
Regards,
Joel

Catégories

En savoir plus sur Troubleshooting dans Help Center et File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by