How to install missing Float center Directional Control valve in Simulink library
2 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
PRABHAKAR KUSHWAHA
le 18 Nov 2019
Modifié(e) : Kavya Vuriti
le 17 Jan 2020
I am unable to find the Float center Directional Control valve in simulink library as it is given in help-documentation.
0 commentaires
Réponse acceptée
Kavya Vuriti
le 17 Jan 2020
Modifié(e) : Kavya Vuriti
le 17 Jan 2020
Hi,
The configuration highlighted in the figure can be obtained by setting values of opening offset parameters as given against the configuration. You can use a 4-way directional valve block and double click on it to open block parameters dialog box. In the opening offsets tab, you can set opening offset values to obtain required configuration.
0 commentaires
Plus de réponses (0)