Change the capacity of the battery using Generate Parameter Data for Equivalent Circuit Battery Block

1 vue (au cours des 30 derniers jours)
Hi,
I am trying to find out the battery parameters for 5RC pairs using Generate Parameter Data for Equivalent Circuit Battery Block (https://in.mathworks.com/help/autoblks/ug/generate-parameter-data-for-estimations-circuit-battery-block.html) . Could someone explain me where to change the capacity of the battery? I wish to use a 40Ah battery. The default battery capacity used in the script is 10Ah.
Regards,
Sumukh

Réponses (1)

Javier Gazzarri
Javier Gazzarri le 8 Jan 2020
Dear Sumukh,
The capacity in that block is Battery capacity table. On line 200 of the script Example_DischargePulseEstimation.m, you can define the capacity value.
Please let me know if this answers your question and if you need any further help.
Best regards,
Javier Gazzarri
  1 commentaire
Sumukh Surya
Sumukh Surya le 10 Jan 2020
Dear Javier,
Thanks for the reply :)
I was able to change the capacity of the battery by running the .file step by step
Regards,
Sumukh