pid tunning of mimo system
Afficher commentaires plus anciens
hi guys!
I want to control my robot which has six actuators, but the outputs does not follow the consign.
here's my Shema bloc and the code

s = tf('s') ;p= 500*pi/1.5 ;
R=4 ;L=2.75E-6 ;K= 0.0274 ;J= 3.2284E-6 ;f= 3.5077E-6 ;
x=[1;1;1;1;1;1];
g=(p*K)/(2*pi*((R+L*s)*(f+J*s)+K^2));
H=double((jac_direct(x)))*g*1e-16; %this is my plant
H.InputName = {'u1','u2','u3','u4','u5','u6'};
H.OutputName = 'y';
D = tunableGain('Decoupler',eye(6));
D.u = 'e';D.y = {'p1','p2','p3','p4','p5','p6'};
C1 = tunablePID('C1','pid');
C1.u = 'p1'; C1.y = 'u1';
C2 = tunablePID('C2','pid');
C2.u = 'p2'; C2.y = 'u2';
C3 = tunablePID('C3','pid');
C3.u = 'p3'; C3.y = 'u3';
C4 = tunablePID('C4','pid');
C4.u = 'p4'; C4.y = 'u4';
C5 = tunablePID('C5','pid');
C5.u = 'p5'; C5.y = 'u5';
C6 = tunablePID('C6','pid');
C6.u = 'p6'; C6.y = 'u6';
Sum = sumblk('e = r - y',6);
C0 = connect(C1,C2,C3,C4,C5,C6,D,Sum,{'r','y'},{'u1','u2','u3','u4','u5','u6'});
wc = 0.1;
TK=TuningGoal.Tracking('r','y',0.05);
OS = TuningGoal.Overshoot({'r'},{'y'},5);
[H,C,gam,info] = looptune(H,C0,wc,OS,TK);
T = connect(H,C,'r','y');
t=0:1/100:100;
U1 = 1*(t>=0);
U=[U1' U1' U1' U1' U1' U1'];
Sys=lsim(T,U,t);
figure,plot(Sys)
Réponses (1)
Arkadiy Turevskiy
le 7 Oct 2020
0 votes
Please contact tech support for help with troubleshooting. Your code does not run without jac_direct.
Catégories
En savoir plus sur PID Controller Tuning dans Centre d'aide et File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!