Connecting 2 signals in Simulink gives an error about data type
1 vue (au cours des 30 derniers jours)
Afficher commentaires plus anciens
I'm trying to show on scope 2 signals - one is bit stream and the other one is the result of multiplication. Occured error is visible in attach.
Without scope3 plugged my model works properly and gives expected results.
Can you halp with that?
0 commentaires
Réponses (1)
Guru Mohanty
le 14 Mai 2020
Hi, error in the model is due to the Product block. Its two inputs are of datatype 'int8' and 'double' and the output is of type 'double', but the wire expects a signal of type 'int8'.This causes an error. In this scenario, you can use Datatype Conversion Block or you can set the Output datatype of the product block.
0 commentaires
Voir également
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!