Connecting 2 signals in Simulink gives an error about data type

1 vue (au cours des 30 derniers jours)
Justyna Fedko
Justyna Fedko le 11 Mai 2020
I'm trying to show on scope 2 signals - one is bit stream and the other one is the result of multiplication. Occured error is visible in attach.
Without scope3 plugged my model works properly and gives expected results.
Can you halp with that?

Réponses (1)

Guru Mohanty
Guru Mohanty le 14 Mai 2020
Hi, error in the model is due to the Product block. Its two inputs are of datatype 'int8' and 'double' and the output is of type 'double', but the wire expects a signal of type 'int8'.This causes an error. In this scenario, you can use Datatype Conversion Block or you can set the Output datatype of the product block.