how does the simulink design verifier creates test case
1 vue (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Ajay krishna Vasanthakumar
le 27 Juil 2020
Commenté : Ajay krishna Vasanthakumar
le 31 Juil 2020
Hello all,
how does the simulink design verifier generates test cases. does it generate the testcase for the given stop in the model to extend the coverage or it alters the stop time ?
Thanks in Advance
Ajay Krishna
0 commentaires
Réponse acceptée
Pat Canny
le 30 Juil 2020
Hi Ajay,
There is an option to "extend" existing test cases with Simulink Design Verifier: https://www.mathworks.com/help/sldv/ug/when-to-extend-existing-test-cases.html
This is a common workflow for users who wish to leverage existing (often manually written) test cases. The test cases are extended in time from the stop time of the manually written test cases.
Otherwise, Simulink Design Verifier will create a new test case with a simulation start time of t=0 .
Hopefully this helps.
Thanks.
- Pat
Plus de réponses (0)
Voir également
Catégories
En savoir plus sur Generate Tests dans Help Center et File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!