Hi,
is it possible to get the latest data (not First In First Out) from the Simulink Real-Time UDP Recive Block? The UDP Receive Block from the Instrument Control Toolbox does that, but is not supported for code generation.
Many Thanks!
0 commentaires
Réponses (1)
Dimitri MANKOV
le 11 Fév 2022
Hi Ingomar,
If you know the maximum number of messages that can be sent on your network between two consecutive executions of the UDP Receive block, you can use that number as the "Receive Width" parameter, and then use the last non-zero value output by the block.