How to resolve this error "illegal rate transition found" of ANN block in Simulink Real-Time workshop
6 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Zakarya Omar
le 14 Sep 2020
Commenté : Zakarya Omar
le 19 Sep 2020
I used nftool to create ANN simulink block to be used in Real-Time workshop. A problem appeared in the ANN block after running the building Real-Time target. the error message is "illegal rate transition found" - sample time [1 0] of nn is different from sample time [0.001 0] of its source.
Knowing that the sampling rate of the training data is 0.001, and the Real-Time system sampling rate is 0.001 as well..
0 commentaires
Réponse acceptée
Nitin Kapgate
le 18 Sep 2020
It appears that the sample time for “nn” is set to [1 0] while that for its source is set to [0.001 0]. In your case, changing the “sample time” for “nn” to [0.001 0] should resolve your issue. Here is a guide that will help you to resolve the Rate Transition issues in Simulink.
Plus de réponses (0)
Voir également
Catégories
En savoir plus sur Development Computer Setup dans Help Center et File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!